Second-degree AV block, Mobitz II

Clinical review pending: written from the sources below, not yet checked by a clinician. Updated 2026-11-22.

Wave size
Lead II · small box: 40 ms across, 0.1 mV up

In one line

The PR interval stays the same on every conducted beat, and then, with no warning, a P wave fails to reach the ventricles.1

Mechanism

  • In Mobitz II, the block is usually below the AV node, in the His bundle or the bundle branches (the His–Purkinje system).1,2
  • That tissue works in an all-or-nothing way: an impulse either passes normally or does not pass at all. So there is no warning stretch of the PR before a beat is dropped.1,2
  • Because the disease sits in the bundle branches, the conducted beats often have a wide QRS or a bundle branch block pattern.2
  • The escape pacemakers below this level are slow and unreliable, so if conduction fails completely the ventricles may pause for a long time before they escape.1
  • Unlike Mobitz I, Mobitz II does not improve with vagal blockade and may even worsen when the atrial rate rises, because more impulses arrive at diseased tissue.2

Epidemiology

  • Mobitz II is much less common than Mobitz I, and it is not a normal finding in athletes: the athlete ECG criteria list it as abnormal, needing further testing.3
  • In a Finnish population cohort, the risk of hospital admission with second- or third-degree AV block rose with older age, male sex, prior myocardial infarction, heart failure, higher systolic blood pressure and higher fasting glucose.4

Causes and risk factors

  • Degeneration and fibrosis of the conduction system with age.1,2
  • Ischemia, for example a large anterior myocardial infarction damaging the bundle branches.1,2
  • Compression by scar tissue or calcification.1
  • Inflammation and infiltration: myocarditis, and infiltrative diseases.1,2
  • After heart surgery or procedures near the conduction system.2
  • Medications rarely cause true Mobitz II; when they seem to, look for disease underneath.2

How to spot it

  1. Rate: atrial rate normal; ventricular rate slower because of dropped beats.1
  2. Regularity: regular P waves; R–R intervals regular apart from the pauses.1
  3. P waves: normal, with occasional P waves that are not followed by a QRS.1
  4. PR interval: fixed on every conducted beat, including the beat right before and right after the dropped beat.1
  5. QRS: often wide, with a bundle branch block pattern.2

Differential diagnosis

  • Mobitz I: the PR lengthens before the dropped beat and is shortest after it.1
  • 2:1 AV block: only one conducted beat between blocked P waves, so you cannot tell whether the PR would have stretched.2
  • High-grade AV block: two or more P waves in a row fail to conduct.2
  • Complete heart block: no P wave conducts; PR varies at random.1
  • Blocked premature atrial contractions: the non-conducted P comes early and looks different.1

Clinical picture

  • Symptoms come from dropped beats and slow rates: tiredness, dizziness, breathlessness, and fainting.1,2
  • Some people have no symptoms until it suddenly progresses to complete block.1

Why it matters

  • Mobitz II can progress to complete heart block and cardiac arrest without warning.1
  • That risk is why it is treated as serious even when the patient feels well.1,2

Management overview

For learning only. This is the shape of care, not a treatment plan; real decisions depend on the patient and the current guideline.

  • Unstable patient: urgent treatment of the slow rate, with temporary pacing if needed. Medicines that act on the AV node are less likely to help a block below it.2
  • Look for reversible causes, such as acute ischemia or inflammation.2
  • Permanent pacemaker: Mobitz II not due to a reversible cause is generally treated with a pacemaker, even without symptoms, to prevent progression to complete block.1,2

Exam pearls

  • Fixed PR, then a sudden drop: Mobitz II.1
  • Mobitz II is "below the node": wide QRS, risky, and needs a pacemaker. Mobitz I is "in the node": narrow QRS, often benign.1,2
  • Always compare the PR right before and right after the dropped beat.1
  • Never call a 2:1 block "Mobitz II" from one strip alone.2

Sources

Where this comes from.

  1. Hall JE, Hall ME. Guyton and Hall Textbook of Medical Physiology, 14th ed. Elsevier; 2021. Ch. 13 (pp. 158–160).
  2. Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay. J Am Coll Cardiol. 2019;74(7):e51–e156. doi.org/10.1016/j.jacc.2018.10.044
  3. Drezner JA, Sharma S, Baggish A, et al. International criteria for electrocardiographic interpretation in athletes: consensus statement. Br J Sports Med. 2017;51(9):704–731. doi.org/10.1136/bjsports-2016-097331
  4. Kerola T, Eranti A, Aro AL, et al. Risk Factors Associated With Atrioventricular Block. JAMA Netw Open. 2019;2(5):e194176. doi.org/10.1001/jamanetworkopen.2019.4176