12-lead notes · ECG Simulator
Left axis deviation
Clinical review pending: written from the sources below, not yet checked by a clinician. Updated 2026-11-22.
In one line
The average direction of ventricular depolarization (the mean QRS axis) swings up and to the patient's left, beyond about −30°, so the QRS is upright in lead I but mostly negative in II and aVF.1,2
Mechanism
- The mean electrical axis is the average direction of the wave of depolarization through the ventricles. Guyton gives a normal mean of about +59°, varying in healthy hearts from about +20° to +100°.1
- The axis shifts toward wherever depolarization is strongest or latest.1
- Left anterior fascicular block (LAFB): if the front branch of the left bundle fails, the upper-left part of the left ventricle is activated last, pulling the axis up and left. The standard criteria for LAFB use an axis between −45° and −90°.2
- Left ventricular hypertrophy: more muscle on the left, and slower spread through it, swing the axis left.1,3
- Left bundle branch block: the right ventricle depolarizes first, leaving a strong vector toward the late left ventricle.1
- Heart position: the axis shifts left at the end of deep expiration, when lying down, and in people with obesity, because the diaphragm pushes the heart into a more horizontal position.1
Epidemiology
Causes and risk factors
- Left anterior fascicular block, often from fibrosis of the conduction system or coronary disease.2
- Left ventricular hypertrophy from hypertension, aortic stenosis or regurgitation.1,3
- Left bundle branch block.1
- Inferior myocardial infarction, where loss of inferior muscle leaves the remaining forces pointing up.4
- Body habitus and posture: obesity, lying down, deep expiration.1
How to spot it
- Lead I: QRS mainly positive.1,2
- Leads II and aVF: QRS mainly negative. If lead II is negative, the axis is beyond about −30°.2
- Look for the cause: a wide QRS (bundle branch block), large voltages (hypertrophy), or Q waves in II, III and aVF (old inferior infarct).1,3
- LAFB pattern: small q in I and aVL, small r in II, III and aVF (qR in aVL, rS in the inferior leads), with a QRS that is not wide.2
Differential diagnosis
Clinical picture
Why it matters
Management overview
For learning only. This is the shape of care, not a treatment plan; real decisions depend on the patient and the current guideline.
Exam pearls
Try it
See it in all 12 leads.
Compare with its lookalikes:
Sources
Where this comes from.
- Hall JE, Hall ME. Guyton and Hall Textbook of Medical Physiology, 14th ed. Elsevier; 2021. Ch. 12 (pp. 148–151, 155).
- Surawicz B, Childers R, Deal BJ, et al. AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the Electrocardiogram, Part III: Intraventricular Conduction Disturbances. Circulation. 2009;119(10):e235–e240. doi.org/10.1161/CIRCULATIONAHA.108.191095
- Hancock EW, Deal BJ, Mirvis DM, et al. AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the Electrocardiogram, Part V: Electrocardiogram Changes Associated With Cardiac Chamber Hypertrophy. Circulation. 2009;119(10):e251–e261. doi.org/10.1161/CIRCULATIONAHA.108.191097
- Wagner GS, Macfarlane P, Wellens H, et al. AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the Electrocardiogram, Part VI: Acute Ischemia/Infarction. Circulation. 2009;119(10):e262–e270. doi.org/10.1161/CIRCULATIONAHA.108.191098
- Kligfield P, Gettes LS, Bailey JJ, et al. Recommendations for the Standardization and Interpretation of the Electrocardiogram, Part I: The Electrocardiogram and Its Technology. Circulation. 2007;115(10):1306–1324. doi.org/10.1161/CIRCULATIONAHA.106.180200