Medi Labz
← All tools
001CardiologyBeta

ECG Simulator

Watch the heart's rhythm shift from normal to arrhythmia, then test yourself with quizzes and diagnosis practice.

Follow the dot. Each wave lights up and says what the heart is doing.

Leads shown in each row
Wave size

Normal sinus rhythm

Every P has a QRS. Regular. 60–100 bpm.

Read more about normal sinus rhythm →
Small box: 40 ms across, 0.1 mV up10.00 s

Measure any gap on the strip.

Playback speed
Sound
Heart conduction diagramA four-chamber heart that lights up in time with the strip. Amber shows muscle depolarizing, spreading from where the beat starts; teal shows it recovering. A schematic teaching drawing, not anatomy to scale.RALARVLVSAAV
AV node: quiet Depolarizing RecoveringPatient's right is on your left.

The whole strip

Press Play, or drag across the strip to step through each wave.

IIIIIIaVRaVLaVF
Limb leads
V1V2V3V4V5V6
Chest leads (from below)

A lead's trace rises when the arrow points toward it and dips when it points away.

Sources

Where this comes from.

  1. Hall JE, Hall ME. Guyton and Hall Textbook of Medical Physiology. Chapters 11–13: the normal ECG and arrhythmias. Chapters 9 and 23: the cardiac cycle and the heart sounds (timing, duration and pitch of S1 and S2).
  2. Costanzo LS. Physiology. Chapter 4: cardiovascular physiology, the electrocardiogram.
  3. Samesima N, et al. Brazilian Society of Cardiology Guidelines on the Analysis and Issuance of Electrocardiographic Reports, 2022.
  4. Surawicz B, et al. AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the Electrocardiogram, Part III: Intraventricular Conduction Disturbances. Circulation, 2009.
  5. Hancock EW, et al. AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the Electrocardiogram, Part V: Chamber Hypertrophy. Circulation, 2009.
  6. Wagner GS, et al. AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the Electrocardiogram, Part VI: Acute Ischemia/Infarction. Circulation, 2009.
  7. Edworthy J. Medical audible alarms: a review. J Am Med Inform Assoc, 2013 (priority-encoded alarms of IEC 60601-1-8, used for the monitor sound).
  8. Liu C, et al. An open access database for the evaluation of heart sound algorithms. Physiol Meas, 2016. Heart mode plays real S1 and S2 recordings from this PhysioNet/CinC Challenge 2016 database, and its ECG-synced recordings set the S1 and S2 timing. Contains information from that database, made available under the ODC Attribution License (opendatacommons.org/licenses/by/1-0).
  9. Hada Y, et al. Echophonocardiographic study of the initial low frequency component of the first heart sound. J Am Coll Cardiol, 1983 (S1 loudness varies beat to beat in arrhythmias).
  10. Xiao HB, Faiek AH, Gibson DG. Re-evaluation of normal splitting of the second heart sound in patients with classical left bundle branch block. Int J Cardiol, 1994.

Wave shapes and amplitudes are illustrative teaching choices, not patient recordings. Timing follows the sources above. Clinical review is pending.